Physics IA Exemplar: Guitar Plectrum Thickness and High E Harmonics | RevisionDojo
Loading document preview...
IB Physics HL Internal Assessment Example
INVESTIGATING THE IMPACT OF GUITAR PLECTRUM
THICKNESS ON THE SOUND PRESSURE LEVEL
DISTRIBUTION ACROSS EIGHT HARMONICS OF THE
HIGH E STRINGHL
Loading scores...
6
Official IB Result
19/24
Criteria A: Research Design
6/6
0
3
6
Criteria StrandsPro
A.1Research question context
Excellent
A.2Methodological considerations for collecting data
Good
A.3Methodological considerations
Good
Criteria Feedback
The student's research question is focused, quantitative, and framed around a clear comparison of plectrum thicknesses and harmonic output.
The student identifies and discusses several relevant variables and controls, which shows that they thought carefully about how to make the investigation workable.
The student's method is detailed enough that another student could follow the overall experimental setup with only minor clarification needed.
The student needs to keep the target string consistent throughout the report, because the question, procedure, and later references do not always match.
Some measured quantities are described imprecisely, especially the difference between wave amplitude, FFT magnitude, and the decibel values produced by the software.
A few methodological choices are still only partly justified, so the investigation would be stronger if the student explained why those settings were selected and how they support valid data collection.
1.1·Weakness
Page 2• Click to view
The dependent variable is named as “wave amplitude,” but the investigation later records Audacity FFT values in decibels. The student should align the wording of the question with the actual measured quantity, because amplitude, FFT magnitude, and dB are not interchangeable terms.
1.2·Strength
Page 2• Click to view
The research question is impressively focused and quantitatively specific. By naming five thicknesses, eight harmonics, and the E4 string, the student creates a narrow enough investigation to be tested empirically rather than remaining purely descriptive.
1.3·Weakness
Page 3• Click to view
This explanation is useful, but the relationship between the FFT output and the reported “Sound Pressure Level” still needs more precision. The student should clarify whether the software gives relative digital magnitude or calibrated sound pressure, because that affects the validity of the dependent variable.
1.4·Weakness
Page 4• Click to view
This conflicts with the research question, which studies the high E string, and with the later procedure that uses the E4 string. The student should make the target string consistent throughout the report, because switching strings changes the fundamental frequency and invalidates direct comparison.
1.5·Strength
Page 4• Click to view
The independent variable is operationalized clearly enough for the investigation to be reproduced. Listing discrete thickness values gives the reader a concrete experimental range rather than a vague description of “thin” versus “thick” picks.
1.6·Weakness
Page 5• Click to view
The method is not internally consistent: this step refers to the 6th string, while the rest of the investigation is framed around the first/high E string. The student needs to standardize the string reference and explain the sticker placement in relation to that same string.
1.7·Question
Page 5• Click to view
What would happen to the recorded harmonic pattern if the microphone distance stayed fixed but the amplifier gain changed? Thinking about this would help the student separate true plectrum effects from recording-system effects.
1.8·Weakness
Page 6• Click to view
The procedure includes repeats, which is good, but it still does not fully specify how trials were selected, rejected, or labeled. Because later processing depends on matching each trial to a thickness and harmonic, the student should describe a clearer trial-recording system.
1.9·Suggestion
Page 6• Click to view
A short justification of why these specific plucking conditions were chosen would strengthen the design. Explaining how 5N and the 4cm displacement were selected would show more deliberate control of variables rather than only procedural control.
Criteria B: Data Analysis
6/6
0
3
6
Criteria StrandsPro
B.1Communication of data recording and processing
Excellent
B.2Consideration of uncertainties
Moderate
B.3Data processing quality
Moderate
Criteria Feedback
The student's raw-data presentation is generally clear and easy to follow, with the repeated trials organised in a way that lets the reader trace the processing pathway.
The student shows meaningful use of averages, error bars, and regression lines, which gives their analysis structure and makes the trends easier to interpret.
The student keeps the same colour coding across tables and graphs, which helps the reader connect each harmonic consistently through the report.
Some labels and units are not precise enough, especially where the software output should be distinguished from calibrated sound-pressure measurements.
A few calculations and uncertainty statements are not explained with enough mathematical clarity for another reader to reproduce them confidently.
The student's processing would be stronger if they tested the suitability of the linear models and treated the trend strengths more carefully instead of relying mainly on the fit values.
2.1·Strength
Page 7• Click to view
The raw-data section makes the processing pathway traceable from recording to FFT output. This is strong communication because the reader can see exactly where the numerical values in later tables came from.
2.2·Weakness
Page 7• Click to view
The unit label is not sufficiently precise for the analysis that follows. The student should distinguish between calibrated sound pressure level and the relative decibel scale produced by the audio software, because the interpretation of the values depends on that distinction.
2.3·Strength
Page 7• Click to view
A separate table for each plectrum thickness is an effective organizational choice. It keeps the repeated measurements readable and makes cross-comparison between thicknesses much easier.
2.4·Weakness
Page 8• Click to view
This sentence is unclear and does not explain how the uncertainty was actually determined. The student should state the exact rule used for uncertainty assignment, because “dispersion” alone is not enough to justify the error bars.
2.5·Weakness
Page 8• Click to view
Several values in the processed table appear inconsistent with the raw data, so the student should verify the arithmetic before relying on the mean table. Accurate processing is essential because any later trend line is only as valid as the numbers entered into it.
2.6·Weakness
Page 8• Click to view
The student states the mean calculation clearly, but the wording is mathematically incomplete because averaging requires summing the five values before dividing by 5. The processing step should be written explicitly so another reader can reproduce it without guesswork.
2.7·Strength
Page 8• Click to view
Using a consistent colour scheme is a strong communication choice. It helps the reader track the same harmonic across the table and graphs without needing to re-check labels repeatedly.
2.8·Weakness
Page 9• Click to view
The analysis relies heavily on R2, but it does not test whether a linear model is the best choice or whether the slope differences are statistically meaningful. The student should go beyond goodness-of-fit and examine uncertainty in the gradients themselves.
2.9·Weakness
Page 9• Click to view
Dividing the data into two groups is sensible, but the student does not explain why the split occurs at the 5th/6th harmonic. A stronger analysis would justify the threshold using the data rather than treating the division as self-evident.
2.10·Strength
Page 10• Click to view
The student correctly notices that the higher harmonics behave differently from the lower ones. Identifying this change in trend is a useful analytical step because it shows the data were not forced into one oversimplified pattern.
Criteria C: Conclusion
2/6
0
3
6
Criteria StrandsPro
C.1Conclusion relevance and support
Moderate
C.2Scientific context comparison
Poor
Criteria Feedback
The student's conclusion stays focused on the research question and refers back to the trends they calculated.
The student does acknowledge uncertainty and recognises that some parts of the pattern are less consistent than others.
The student makes at least some connection to the expected physics of string vibration and harmonic behaviour.
The conclusion is stronger than the evidence fully supports, especially where it implies that the method was fully successful and that the thickness effect is established without qualification.
The link to scientific context is fairly limited and would be more convincing if the student compared their pattern to a clearer acoustic explanation or published expectation.
The student needs to be more careful not to treat a good regression fit as proof of cause, because that does not by itself demonstrate a physically meaningful relationship.
3.1·Question
Page 10• Click to view
If the sign change near the 6th harmonic is central to the conclusion, what physical mechanism could explain why the effect reverses there? Considering that mechanism would make the conclusion more scientifically grounded.
3.2·Weakness
Page 10• Click to view
This claim is not demonstrated mathematically. The student should show how the trend lines were compared with the uncertainty ranges, because simply stating that they “lay within” them does not prove that the trend is statistically secure.
3.3·Strength
Page 10• Click to view
The conclusion stays focused on the stated research question and returns to the key variables. This is effective because it shows the student is answering the investigation rather than drifting into a general summary.
3.4·Strength
Page 10• Click to view
It is strong that the student acknowledges the size of the uncertainty and relates it to the measured value. This shows some awareness that significance depends on scale, not just on whether an error bar exists.
3.5·Weakness
Page 10• Click to view
This conclusion is too strong for the evidence presented. The results suggest a trend, but they do not prove that the methodology was optimal or that all effects are attributable only to plectrum thickness, given the uncontrolled variables and uncalibrated audio measurements.
3.6·Weakness
Page 10• Click to view
The recommendation is unclear because it is not obvious what “they” refers to. The student should specify which uncertainty source or variable should be reduced, and how doing so would improve confidence in the conclusion.
3.7·Weakness
Page 10• Click to view
A high R2 does not by itself establish that the relationship is physically strong or meaningful. The student should avoid treating fit quality as proof of causation and instead connect the trend back to the underlying wave behavior.
Criteria D: Evaluation
5/6
0
3
6
Criteria StrandsPro
D.1Methodological weaknesses
Good
D.2Suggested improvements
Good
Criteria Feedback
The student identifies several specific weaknesses rather than only giving general comments, including issues with manual plucking, microphone quality, and plectrum measurement.
The student's suggested improvements are realistic and clearly connected to the problems they identified.
The student shows awareness that experimental control is central to the reliability of the harmonic data.
Some limitations are described without enough explanation of how strongly they affect the final results compared with other sources of error.
A few improvements are still broad and would be stronger if the student explained exactly how they would reduce the uncertainty in the data.
The student could evaluate the effect of the main weaknesses more directly, especially the ones that are most likely to change the harmonic distribution itself.
4.1·Strength
Page 11• Click to view
Although the wording is imperfect, the improvement is clearly targeted at a real limitation. Replacing the laptop microphone with a better measurement device would reduce one of the main sources of distortion in the spectral data.
4.2·Suggestion
Page 11• Click to view
A stronger suggestion would name the exact equipment and the exact uncertainty it would reduce. For example, specifying a calibrated microphone and fixed amplifier gain would make the improvement operational rather than general.
4.3·Weakness
Page 11• Click to view
This weakness is valid, but it is still quite generic. The student should explain how microphone quality specifically affects the harmonic distribution, for example by changing sensitivity across frequencies rather than simply making the recording “worse.”
4.4·Weakness
Page 11• Click to view
This is an important limitation, but the impact is stated too broadly. The student should specify whether the thickness uncertainty mainly weakens the slope, the separation between neighbouring thickness groups, or the confidence in the reversal around the 6th harmonic.
4.5·Strength
Page 11• Click to view
This is a relevant and specific strength because it targets a real source of variation in manual plucking. The comment shows awareness that the quality of the data depends on controlling the input conditions, not just on measuring outputs.
4.6·Weakness
Page 11• Click to view
This limitation is relevant, and it should be ranked as one of the most serious because it directly changes the excitation of the string. The student should explain that these uncontrolled plucking variables likely affect the harmonic spectrum more strongly than small thickness differences do.
4.7·Strength
Page 11• Click to view
The student correctly identifies repeat trials as a strength, and the justification is sensible. Repetition helps reduce random error and makes the mean values more dependable.
4.8·Suggestion
Page 11• Click to view
To strengthen this improvement, the student should explain how the mechanical arm would be standardized — for example, fixed release angle, displacement, and plucking force. That would make the link between the weakness and the solution much more convincing.
4.9·Weakness
Page 11• Click to view
This is a reasonable extension, but it is not yet framed as an evaluation of the current method. The student should explain whether more harmonics would increase reliability, reveal a threshold effect, or test whether the sign change is sustained beyond the 8th harmonic.